Bullroarers

From Robert-Depot
Revision as of 08:31, 10 September 2014 by Rtwomey (talk | contribs) (OSC Addressing)

Jump to: navigation, search

Addressing Scheme

21 bullroarer nodes with single server/controller system.

  • Node Addresses: 192.168.3.1 - 192.168.3.21
  • Server/Controller Address: 192.168.3.100

OSC Addressing

Introduction to Open Sound Control - http://opensoundcontrol.org/introduction-osc

  • Each bullroarer node has a base address /br/NUM where NUM is 1-21.
  • They can send 4 messages:
    • /br/1/range, integer, 0-1024. Analog sensor reading from ultrasonic rangefinder from 0-1024.
    • /br/1/limit, integer, 0 or 1. State of limit switch, sent when button is pressed or released. Switches are active low, so the value is 0 (LOW) when the button is pressed, 1 (HIGH) when the button is released.
    • /br/1/relay, integer, 0 or 1. State of motor control relay. Sent when relay state changes. Relays are active low, so a value of 0 (LOW) means the relay is on, 1 (HIGH) means the relay is off.
    • /br/1/config, integer, integer, integer.
      • First value is auto mode, 0 for "off", 1 for "on".
      • Second value is max range, 0 - 1024. This is a threshold value for the lower limit of bullroarer travel. When in auto mode, a sensor reading larger than this value will trigger the relay to turn the motor back on and raise the bullroarer.